1" AND 1 ½" MECHANICALLY SEAMED PANEL The A 1300 roofing panel series offers the same
architectural detailing capability as architectural snap lock
roofing panels with the structural strength and weather tightness
advantages of a mechanically seamed system. It allows for smooth
transitions from the roof surfaces to mansards, fascia, walls and
soffits.
Structural | No |
| Architectural detail capability | Yes |
| Tight radius curving capacity | Use the
C1300 system |
| Shallow slope (less than 3"/12") | Yes |
| Narrow seam | Yes |
| Wide seam | No |
| Flush seam | No |
| Snap-lock seam | No |
| Mechanical seam | Yes |
| Good transition between roof and mansard or fascia | No |
| UL-90 tested | Yes |
| Florida Building Code Compliant | Yes |
| ASTM water & air infiltration tested | Yes |
| Dade County tested | Yes |
| ASTM E-1592 tested | Yes |
| Weathertightness warranties | Yes |
| FM Tested | No |